You cannot select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
ansible/test/units/modules/network/ironware/fixtures/show_version

93 lines
4.7 KiB
Plaintext

System Mode: MLX
Chassis: MLXe 4-slot (Serial #: BGD2503J01F, Part #: 40-1000363-04)
NI-X-HSF Switch Fabric Module 1 (Serial #: BEW0444H01V, Part #: 60-1001512-10)
FE 1: Type fe600, Version 1
Switch Fabric Module 1 Up Time is 203 days 4 hours 44 minutes 54 seconds
NI-X-HSF Switch Fabric Module 2 (Serial #: BEW0432H06S, Part #: 60-1001512-10)
FE 1: Type fe600, Version 1
Switch Fabric Module 2 Up Time is 203 days 4 hours 44 minutes 54 seconds
==========================================================================
SL M1: BR-MLX-MR2-M Management Module Active (Serial #: BVP0425L02W, Part #: 60-1002374-07):
Boot : Version 5.8.0T165 Copyright (c) 1996-2014 Brocade Communications Systems, Inc.
Compiled on May 18 2015 at 13:02:10 labeled as xmprm05800
(521590 bytes) from boot flash
Monitor : Version 5.8.0T165 Copyright (c) 1996-2014 Brocade Communications Systems, Inc.
Compiled on May 18 2015 at 13:01:40 labeled as xmb05800
(539721 bytes) from code flash
IronWare : Version 5.8.0fT163 Copyright (c) 1996-2014 Brocade Communications Systems, Inc.
Compiled on Feb 24 2017 at 02:54:38 labeled as xmr05800fb
(9983317 bytes) from Primary
Board ID : 00 MBRIDGE Revision : 37
1666 MHz Power PC processor 7448 (version 8004/0202) 166 MHz bus
512 KB Boot Flash (MX29LV040C), 128 MB Code Flash (MT28F256J3)
4096 MB DRAM INSTALLED
4096 MB DRAM ADDRESSABLE
Active Management uptime is 203 days 4 hours 44 minutes 54 seconds
==========================================================================
SL M2: BR-MLX-MR2-M Management Module Standby (Serial #: BVP0407L00D, Part #: 60-1002374-07):
Boot : Version 5.8.0T165 Copyright (c) 1996-2014 Brocade Communications Systems, Inc.
Compiled on May 18 2015 at 13:02:10 labeled as xmprm05800
(521590 bytes) from boot flash
Monitor : Version 5.8.0T165 Copyright (c) 1996-2014 Brocade Communications Systems, Inc.
Compiled on May 18 2015 at 13:01:40 labeled as xmb05800
(539721 bytes) from code flash
IronWare : Version 5.8.0fT163 Copyright (c) 1996-2014 Brocade Communications Systems, Inc.
Compiled on Feb 24 2017 at 02:54:38 labeled as xmr05800fb
(9983317 bytes) from Primary
Board ID : 00 MBRIDGE Revision : 37
1666 MHz Power PC processor 7448 (version 8004/0202) 166 MHz bus
512 KB Boot Flash (MX29LV040C), 128 MB Code Flash (MT28F256J3)
4096 MB DRAM INSTALLED
4096 MB DRAM ADDRESSABLE
Standby Management uptime is 203 days 4 hours 44 minutes 15 seconds
==========================================================================
SL 1: NI-MLX-10Gx8-M 8-port 10GbE (M) Module (Serial #: BEQ0403G05E, Part #: 60-1001587-13)
(LID: dgsFJFIiFKg)
Boot : Version 5.8.0T175 Copyright (c) 1996-2014 Brocade Communications Systems, Inc.
Compiled on May 18 2015 at 13:02:24 labeled as xmlprm05800
(449481 bytes) from boot flash
Monitor : Version 5.8.0T175 Copyright (c) 1996-2014 Brocade Communications Systems, Inc.
Compiled on May 18 2015 at 13:02:40 labeled as xmlb05800
(568745 bytes) from code flash
IronWare : Version 5.8.0fT177 Copyright (c) 1996-2014 Brocade Communications Systems, Inc.
Compiled on Feb 24 2017 at 03:02:10 labeled as xmlp05800fb
(9304807 bytes) from Primary
FPGA versions:
Valid PBIF Version = 2.24, Build Time = 4/7/2016 14:16:00
Valid XPP Version = 0.08, Build Time = 6/27/2016 10:36:00
MACXPP40G 0
MACXPP40G 1
1333 MHz MPC MPC8548 (version 8021/0022) 533 MHz bus
512 KB Boot Flash (MX29LV040C), 64 MB Code Flash (MT28F256J3)
1024 MB DRAM, 8 KB SRAM
LP Slot 1 uptime is 203 days 4 hours 44 minutes 12 seconds
==========================================================================
SL 2: BR-MLX-1GFx24-X 24-port 1GbE SFP Module (Serial #: BND0415H003, Part #: 60-1001892-11)
License: (LID: dpfFJGKjFFI)
Boot : Version 5.8.0T175 Copyright (c) 1996-2014 Brocade Communications Systems, Inc.
Compiled on May 18 2015 at 13:02:24 labeled as xmlprm05800
(449481 bytes) from boot flash
Monitor : Version 5.8.0T175 Copyright (c) 1996-2014 Brocade Communications Systems, Inc.
Compiled on May 18 2015 at 13:02:40 labeled as xmlb05800
(568745 bytes) from code flash
IronWare : Version 5.8.0fT177 Copyright (c) 1996-2014 Brocade Communications Systems, Inc.
Compiled on Feb 24 2017 at 03:02:10 labeled as xmlp05800fb
(9304807 bytes) from Primary
FPGA versions:
Valid PBIF Version = 4.04, Build Time = 11/10/2014 22:10:00
Valid XPP Version = 1.03, Build Time = 6/30/2016 10:37:00
Valid STATS Version = 0.09, Build Time = 11/21/2010 14:52:00
BCM56512GMAC 0
BCM56512GMAC 1
666 MHz MPC MPC8541E (version 8020/0020) 333 MHz bus
512 KB Boot Flash (MX29LV040C), 16 MB Code Flash (MT28F128J3)
1024 MB DRAM, 8 KB SRAM
LP Slot 2 uptime is 21 days 20 hours 23 minutes 19 seconds
==========================================================================
All show version done