- Use predictable VM name during the tests (test_vm1, test_vm2 and
test_vm2). This to simplify the teardown of the newly created resource
before the next test.
- Update the documentation to explain the new requirement
- Avoid VM creation with `with_items` when it's not mandatory. This to:
- speed up the test execution, our hypervisors have limited resources
- simplify the teardown
- Remove `create_d1_c1_f0_env.yml`, the test was just testing how Ansible
pass environment variables.
- Correct the name for the `f0` variable (`f1`)
- Fix the DVS tests, the hosts can now reach the dvswitch1 vswitch
- Provision the VM with a poweroff status, this to improve the
idempotency and sleep up the tests
- Avoid the use of `prepare_vmware_tests` to prepare virtual machines
when we just need one machine
vmware_guest accepts 0MB as valid value for memory reservation in
virtual machine hardware configuration. This fixes the regression
introduced via 193f69064f.
Fixes: #59190
Signed-off-by: Abhijeet Kasurde <akasurde@redhat.com>
- In order to keep the integration with `ansible-test`, we prefer to avoid any
interaction with the Ansible inventory file.
- split up the prepare_vmware_tests/defaults/main.yml in two
configuration files: one for vcsim and one for a real environment
- remove all the access to hostvars
- directly interact with the ESXi to mount/umount the datastore
https://github.com/ansible/ansible/pull/56516
- record the virtual machine folder in the environment configuration
- vmware_guest_move: Use https://github.com/ansible/ansible/pull/55237
Refactoring of the following roles to make use of the new
`prepare_vmware_tests` role.
- `vmware_guest`
- `vmware_guest_boot_facts`
- `vmware_guest_custom_attribute_defs`
- `vmware_guest_customization_facts`
- `vmware_guest_disk_facts`
- `vmware_guest_facts`
- `vmware_guest_find`
- `vmware_guest_move`
- `vmware_guest_powerstate`
- `vmware_guest_snapshot`
- `vmware_guest_snapshot_facts`
- `vmware_guest_tools_wait`
This patch depends on: https://github.com/ansible/ansible/pull/55719
Original PR: https://github.com/ansible/ansible/pull/54882
* Add parameters to module vmware_guest for conversion of disk to thin or thick when vm is cloned or deployed with template
* unit test for convert clone vm
Co-Authored-By: chris93111 <christopheferreira@ymail.com>
linked_clone requires snapshot_src parameter. This fix makes them required_together
and update documentation. Also, testcase is added.
Fixes: #42349
Signed-off-by: Abhijeet Kasurde <akasurde@redhat.com>
* VMware: Allow user to select disk_mode
This fix allows user to select disk modes for given disk configuration
in the given VM.
Fixes: #37749
Signed-off-by: Abhijeet Kasurde <akasurde@redhat.com>
* Review comments
Signed-off-by: Abhijeet Kasurde <akasurde@redhat.com>
Check datatype of device instead of comparing them directly in
vmware_guest. Also, added testcases to check this behavior.
DPVG is not supported in current version vcsim
Signed-off-by: Abhijeet Kasurde <akasurde@redhat.com>
* VMware: apply correct value for datacenter in TC
Signed-off-by: Tim Steinbach <tim@nequissimus.com>
Signed-off-by: Abhijeet Kasurde <akasurde@redhat.com>
* Adding support for vApp properties.
* vm specification updated only if changes have to be applied. I.e. subsequent updates with the same data will not trigger changed state
* Auxiliary variables renamed, hope this makes the code more readable
* Integration tests changed - re-adding the same properties test not implemented, but tested on real vCenter deployment
* fixing documentation "version_added" for the feature
* Addressing reviewers comments #2:
* documentation updated with the only meaningful value for "option" attribute - "remove"
* Fixed improperly handled case when user requested "add" operation for existent property
* vApp configuration is updated only with properties that contains changes, not with all properties requested by user
This fixes, cloning operation where template or existing VM
does not have network or DVPG. Also, adds some strict type checking in
network parameters.
Signed-off-by: Abhijeet Kasurde <akasurde@redhat.com>
This fix adds a verbose message about non-existent VM when specified
with operation, due to idempotency we can not detect correct state.
Fixes: #27384
Signed-off-by: Abhijeet Kasurde <akasurde@redhat.com>
This fix adds ability to set MAC address maunally. Before adding
any MAC address, the value is validated. If value is not valid, then
MAC address is set to vCenter generated MAC address.
Also, added integration tests for this change.
Fixes: #21161
Signed-off-by: Abhijeet Kasurde <akasurde@redhat.com>
* Initial CD-ROM support
* create cdrom bugfix
* Improving CDROM change detection and fixing template creation bug
Running MarkAsTemplate on an existing template will fail with an error
* Better change detection for guest ID
Should only mark a change in case it actually changes
* Adding integration tests
* Pep8 compliance fixes
* Adding CDROM support, including iso, client and none types
* Updating added release version for CDROM option
* Save the serialized values instead of their types
* Add tests for creating and modifying VMs without using a template
* Remove blank line
* Add tests for vm deletion
* vmware_guest: fixes for cache objects and datacenter association
* find_all_objs was only looking for datastores
* Clear the result if it's datacenter is not correct.
* Re-enable pyvmomi installation
Addresses #25011
Addresses #26511
* Slight refactor on vmware_guest to fix path searching and vcsim compatibility.
* Clean up pep8 errors
* Fix more pep8 issues
* Add assertions
* Remove debug failure
* Update docsting for folder with examples
* Revise _get_vm_prop based on suggestions
* Implement folder walker to find a folder path
* More enhancements for datacenter->datacenter cloning
* Fix a few pep8 issues
* Remove useless check for subclass of None
* Fix a few suggestions
* Move serialize_spec to a util function
* Group exceptions together
Fixes#25011