Ensure we already create the `test_vm3` VM in the `{{ f0 }}` directory.
This to be sure the teardown playbook will be able to clean it up at the
end. This to avoid problem like this one:
```
Multiple virtual machines with same name [test_vm3] found, Folder value is a required parameter to find uniqueness of the virtual machine
```
In the VMware tests, we call the datastores `ds1` and `ds2`. The first
one is read-only, the second is read-write and can be used to deploy
VMs. The naming convention was not clear enough and source of a lot
confusion and mistake.
We now have two better names:
- ro_datastore, which is ... read-only
- rw_datastore, the one that we can use to deploy new VM.
Add support for create or re-configure VM with multiple CD-ROMs attaching to IDE controller now, will implement SATA controller support later.
parameters can be set as below:
cdrom:
- controller_type: ide
controller_number: 0
unit_number: 0
type: client
If a VM has an attached CDROM, `backing` attribute of the CDROM will
be defined.
As a result, we cannot just loop `vm_obj.config.hardware.device` and check
for the existance of the attribute to decide if the entry is a
harddrive.
Instead, we check the type of the device, and only keep the
`vim.vm.device.VirtualDisk` disk.
This issue is actually breaking our test-suite with regular environment
because we keep a Fedora ISO attached to the VM.
- Use predictable VM name during the tests (test_vm1, test_vm2 and
test_vm2). This to simplify the teardown of the newly created resource
before the next test.
- Update the documentation to explain the new requirement
- Avoid VM creation with `with_items` when it's not mandatory. This to:
- speed up the test execution, our hypervisors have limited resources
- simplify the teardown
- Remove `create_d1_c1_f0_env.yml`, the test was just testing how Ansible
pass environment variables.
- Correct the name for the `f0` variable (`f1`)
- Fix the DVS tests, the hosts can now reach the dvswitch1 vswitch
- Provision the VM with a poweroff status, this to improve the
idempotency and sleep up the tests
- Avoid the use of `prepare_vmware_tests` to prepare virtual machines
when we just need one machine
vmware_guest accepts 0MB as valid value for memory reservation in
virtual machine hardware configuration. This fixes the regression
introduced via 193f69064f.
Fixes: #59190
Signed-off-by: Abhijeet Kasurde <akasurde@redhat.com>
- In order to keep the integration with `ansible-test`, we prefer to avoid any
interaction with the Ansible inventory file.
- split up the prepare_vmware_tests/defaults/main.yml in two
configuration files: one for vcsim and one for a real environment
- remove all the access to hostvars
- directly interact with the ESXi to mount/umount the datastore
https://github.com/ansible/ansible/pull/56516
- record the virtual machine folder in the environment configuration
- vmware_guest_move: Use https://github.com/ansible/ansible/pull/55237
The use of the `hostvars[esxi1].ansible_host` was attempt to use
different hostname and IP address. But it's actually the source of
more problems.
VMware expects to be able to resolvable the host name. This means, that
if someone wants to run the test-suite, s/he needs to use a DNS or
update the `/etc/hosts` files on the different hosts.
Refactoring of the following roles to make use of the new
`prepare_vmware_tests` role.
- `vmware_guest`
- `vmware_guest_boot_facts`
- `vmware_guest_custom_attribute_defs`
- `vmware_guest_customization_facts`
- `vmware_guest_disk_facts`
- `vmware_guest_facts`
- `vmware_guest_find`
- `vmware_guest_move`
- `vmware_guest_powerstate`
- `vmware_guest_snapshot`
- `vmware_guest_snapshot_facts`
- `vmware_guest_tools_wait`
This patch depends on: https://github.com/ansible/ansible/pull/55719
Original PR: https://github.com/ansible/ansible/pull/54882
Due to changes in https://github.com/ansible/ansible/pull/45412
vmware_guest testcase delete_vm failed. This patch will fix that testcase.
Signed-off-by: Abhijeet Kasurde <akasurde@redhat.com>
* Add parameters to module vmware_guest for conversion of disk to thin or thick when vm is cloned or deployed with template
* unit test for convert clone vm
Co-Authored-By: chris93111 <christopheferreira@ymail.com>
* rewrite get_resource_pool method for correct resource_pool selection
* only keep name if path is given for cluster, esxi_hostname or resource_pool
* Revert "only keep name if path is given for cluster, esxi_hostname or resource_pool"
* This reverts commit 50293ec763c024b0eaceac5d775ccc0ad3ff8bd7.
* if the name argument contains a path, only use the last part for matching
* remove path from cluster argument in tests
* remove find_objs in favour of reusing find_obj with an extra folder argument
* fix find_obj ignoring first if name is not given
* Refactoring related to network device
* Assign unique random temporary key while creating SCSI or/and IDE controller devices
* Add testcase for this change
Fixes: #38679
Signed-off-by: Abhijeet Kasurde <akasurde@redhat.com>
* Update Shippable integration test groups.
* Update integration test group aliases.
* Rebalance AWS and Azure tests with extra group.
* Rebalance Windows tests with another group.
linked_clone requires snapshot_src parameter. This fix makes them required_together
and update documentation. Also, testcase is added.
Fixes: #42349
Signed-off-by: Abhijeet Kasurde <akasurde@redhat.com>
* VMware: Allow user to select disk_mode
This fix allows user to select disk modes for given disk configuration
in the given VM.
Fixes: #37749
Signed-off-by: Abhijeet Kasurde <akasurde@redhat.com>
* Review comments
Signed-off-by: Abhijeet Kasurde <akasurde@redhat.com>
* leave vmware_guest_powerstate tests enabled, but revert changes from: 66743f33
* leave VM poweroff tests enabled, but revert changes from: 87d6bdaf
* bumped 'vcenter-test-container' version to '1.3.0'
* updated test task names based on PR feedback
Check datatype of device instead of comparing them directly in
vmware_guest. Also, added testcases to check this behavior.
DPVG is not supported in current version vcsim
Signed-off-by: Abhijeet Kasurde <akasurde@redhat.com>
* VMware: apply correct value for datacenter in TC
Signed-off-by: Tim Steinbach <tim@nequissimus.com>
Signed-off-by: Abhijeet Kasurde <akasurde@redhat.com>
If user does not specify any network type then set network type
to dhcp. There are additional checks around 'ip', 'netmask' and
'type' in network spec.
Fixes: #38466
Signed-off-by: Abhijeet Kasurde <akasurde@redhat.com>